| Troubleshooting for Stub Holder |
Please see the operation manual
Cause |
Solution / Countermeasures |
| Wrong choice of collet. |
Check collet's type and size. |
| Unable to mount to spindle. |
|
|
Cause |
Solution / Countermeasures |
Spindle dimension is different from standard
dimension. |
Check spindle dimension. |
| Seized or adhered chip and dust to holder
shank, spindle I.D. |
Cleaning of holder shank, spindle I.D. |
| Scratch or dent exists in spindle I.D. or
holder shank. |
・Replace holder or repair spindle.
・Touching up of area in question(rubbing off with sand paper
#1000 and above)
Correction (grinding) by NT TOOL is not possible. |
| In the case of KD series, end face to end
face dimension between spindle and finger
bolt is longer than specified dimension. |
・Check spindle dimension.
・Make spacer thicker to specified dimension. |
In the case of KH series, spindle collar thickness
is larger than specified dimension. |
Repair spindle. |
| Excessive play when mounting
into spindle. |
|
|
Cause |
Solution / Countermeasures |
Spindle dimension is different from standard
dimension. |
Check spindle dimension. |
In the case of KH series, spindle collar thickness
is smaller than specified dimension. |
Repair spindle. |
| In the case of KH series, spindle mounting
is not proper due to functional failure of operating
sleeve. |
・When installing, push operating sleeve down to bring it into
position for secure mounting.
・Cleaning of operating sleeve I.D. |
| In the cases of KH-A, KH series, rubber
damper is deteriorated. |
Ask NT for repair.(In some cases, irrepairable.) |
| In the case of KH-E series, steel ball is worn. |
Ask NT for repair.(In some cases, irrepairable.) |
| In the case of KD series, finger collet taper
is worn. |
Replacement of finger collet assembly. |
| In the case of KD series, finger collets are
broken. |
Replacement of finger collet assembly. |
| In the case of KD series, end face to end
face dimension between spindle and finger
bolt is shorter than specified dimension. |
・Check spindle dimension.
・Make thickness of aspacer adjust to specified dimension. |
| Holder comes off from spindle. |
|
|
Cause |
Solution / Countermeasures |
In the case of KH/EC series, coolant pressure
is higher than specified pressure. |
・Reduce coolant pressure.
・Check specified coolant pressure. |
| In the case of KH series, spindle mounting
is not proper due to functional failure of operating
sleeve. |
・When installing, push operating sleeve down to bring it into
position for secure mounting.
・Cleaning of operating sleeve I.D. |
| Coolant is leaking or there is no
coolant output. |
|
|
Cause |
Solution / Countermeasures |
KH/EC is not being used.
(Stub holders other than KH/EC are not
compatible with center-thru coolant.) |
Use KH/EC.
・For high coolant pressure KH/EC1type
・For low coolant pressure KH/EC2 type |
| Coolant pressure is higher than specified
pressure. |
Use coolant at a pressure equal to or lower than maximum
pressure allowed. |
Collets compatible with center-thru coolan
(OH or C type collets) are not being used. |
Use OH or C type collets.
・OH type ・・・ Center through
・C type ・・・ Collet through |
| Coolant cap “O” ring is deteriorated or
worn. |
Replacement of O-ring. |
| Cutting tool comes off or slips. |
|
|
Cause |
Solution / Countermeasures |
| Large cutting resistance to chucking force. |
・Revision of cutting conditions (Decrease cutting resistance.)
a : Higher rotation speed or lower feed rate
(Approx. 20%)
b : Lower cutting depth
・Shorter tool projection length |
| Insufficient tightening of cap nut |
・Keep recommended torque value for tightening cap nut.
・Use torque wrench. |
| Tightening not sufficient due to cap rotary
ring failure. |
Replacement of cap nut. |
Insufficient tightening of cap nut because of
increased friction in the thread part (Tightening
of collets not enough.) |
Apply oil (grease) on the thread part after cleaning it. |
| Tool tang does not fit into preset driver
groove due to dimensional differences. |
・Check tool tang dimension and preset driver groove dimension.
・Replacement of preset driver. |
Cause |
Solution / Countermeasures |
| Spindle and holder have rattling. |
See Problem: “Excessive play when mounting into spindle” in
the trouble column and reduce play (clearance) to appropriate level. |
Adhered chip and dust to spindle end surface
or holder end surface. |
Cleaning of spindle end surface or holder end surface. |
| Poor chucking accuracy of collet. |
Replacement of collets. |
| Dust seizing in collet insertion area. |
Cleaning of collet insertion area. |
| Scratch or dent in holder I.D. |
Replacement of holder. |
| Scratch or dent on collet I.D. and O.D. |
Replacement of collet |
| Insufficient chucking length. |
Keep minimum insertion length.
(collet ID length must be filled.) |
| Poor accuracy of cutting tool. |
Tool replacemen. |
| Dust seizing in cap nut thread. |
Cleaning of thread part, applying grease. |
Malfunction of rotor ring of cap nut.
(Rotor ring will not rotate smoothly.) |
・Cleaning of cap nut.
(so that rotor ring will rotate smoothly.)
・Replacement of cap nuts. |
Cause |
Solution / Countermeasures |
Cutting resistance is too high in comparison
with chuck's rigidity |
・Revision of cutting conditions (Decrease cutting resistance.)
a : Higher rotation speed or lower feed rate
(Approx. 20%)
b : Lower cutting depth
・Shorter tool projecti |
| When end-milling with series KH-E, KD-T,
The amount of cutting is a little, the end mill runs away, and the slipping phenomenon on the grinding surface has happened. |
Revision of cutting conditions (Increase cutting resistance.)
a : Higher feed rate or lower rotation
(Approx. 20%)
b : Higher cutting depth |
| Bending moment is too large. |
Shorter tool projection length |
| Spindle and holder have rattling. |
See Problem: “Excessive play when mounting into spindle” in
the trouble column and reduce play (clearance) to appropriate level. |
| Holder does not come off from
spindle. |
|
|
Cause |
Solution / Countermeasures |
| Deposition of fretting, rust and/or adhered
coolant residual. |
Cleaning of spindle and holder shank. |
| In the case of KH series, operating sleeve
failure. |
Cleaning of operating sleeve I.D. |
|